0x2003 Motor specific settings
Please refer to your motor's data sheet for the specific values.
| Name | Index:Sub | Type | Bit Size | Min Data | Max Data | Default Data | Unit | Access | PDO Mapping | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Pole pairs | 0x2003:1 | USINT | 8 | 1 | readwrite | ||||||||
|
Number of magnetic pole pairs used in the motor. Please refer to your motor datasheet for this value. |
|||||||||||||
| Name | Index:Sub | Type | Bit Size | Min Data | Max Data | Default Data | Unit | Access | PDO Mapping | ||||
| Torque constant | 0x2003:2 | DINT | 32 | 1 | μNm/A | readwrite | |||||||
|
The motor's torque constant is given by the motor design it defines the torque generated per effective current(rms). The value needs to be configured in μNm/Arms |
|||||||||||||
| Name | Index:Sub | Type | Bit Size | Min Data | Max Data | Default Data | Unit | Access | PDO Mapping | ||||
| Phase resistance | 0x2003:3 | DINT | 32 | 1 | μΩ | readwrite | |||||||
|
The resistance between motor terminal and motor neutral point. It is equal to half of "phase to phase resistance" or "line to line resistance". |
|||||||||||||
| Name | Index:Sub | Type | Bit Size | Min Data | Max Data | Default Data | Unit | Access | PDO Mapping | ||||
| Phase inductance | 0x2003:4 | DINT | 32 | 1 | μH | readwrite | |||||||
|
The inductance between motor terminal and motor neutral point. It is equal to half of "phase to phase inductance" or "line to line inductance". |
|||||||||||||
| Name | Index:Sub | Type | Bit Size | Options | Unit | Access | PDO Mapping | ||||||
| Motor phases inverted | 0x2003:5 | BOOL | 1 |
|
readwrite | ||||||||
|
Use this parameter only when you have a negative velocity or feedback increment with the positive torque increment. |
|||||||||||||