0x2113 Encoder 2 feedback

Feedback of the encoder configured as Encoder 2

Name Index:Sub Type Bit Size Min Data Max Data Default Data Unit Access PDO Mapping
Raw position 0x2113:1 UDINT 32 0 Inc readonly (default) Transmit PDO (Inputs)

Position value received by the encoder before any processing. In case of absolute encoders is the value read from the encoder (with or without MT depending on the encoder type). In case of incremental, it will be a running counter referenced to the position that the encoder had on startup. This value is not affected by polarity or ST offset.

Name Index:Sub Type Bit Size Min Data Max Data Default Data Unit Access PDO Mapping
Adjusted position 0x2113:2 DINT 32 0 Inc readonly (default) Transmit PDO (Inputs)

Encoder absolute position (referenced to the index) once Singleturn offset and Sensor polarity are applied. For incremental encoders, this position will be zero until the index has been found.

Name Index:Sub Type Bit Size Min Data Max Data Default Data Unit Access PDO Mapping
Velocity 0x2113:3 DINT 32 RPM readonly (default) Transmit PDO (Inputs)