0x605A Quick stop option code
Indicates what action is performed when the quick stop function is executed. The slow down ramp is the deceleration value of the used mode of operations. The table below shows the value definitions for the function.
| Value
|
Definition
|
| 0 |
Disable drive function |
| 2 |
Slow down on quick stop ramp and transit into switch on disabled |
| 6 |
Slow down on quick stop ramp and stay in quick stop active |
| Name |
Index:Sub |
Type |
Bit Size |
Options |
Unit |
Access |
PDO Mapping |
| Quick stop option code |
0x605A:0 |
INT |
16 |
| Disable Drive Function |
0 |
| Slow down on quick stop ramp and transit into switch on disabled |
2 |
| Slow down on quick stop ramp and stay in quick stop active |
6 |
|
|
readwrite |
|