On-site installation guide

Please regard this information when installing the Node.

Installation specifications Node 400 Node 1000 Node 2000
E-File number E506869
Rating in Volt 12-48 V
Rating in Ampere 13.2 A RMS 33 A RMS 66 A RMS
Short circuit current rating 5k A
Maximum Surrounding Air Temperature 40° C
Torque Values for Terminal screws 0.5 - 0.6 Nm (4.4 lbf∙in)
Short circuit rating and fuse type Listed Class T Fuse, rated min. 160Vdc 50A 20kA. (JDDZ/7.E81895)
Temperature rating of field installed conductors >85° N/A

Field wiring terminal marking

../../../../../_images/e1_terminal_designation.png

Attention

These products are intended for operation within circuits not connected directly to the supply mains (galvanically isolated from the supply, i.e. on transformer secondary).

Attention

Integral solid state short circuit protection does not provide branch circuit protection. Branch circuit protection must be provided in accordance with the National Electrical Code and any additional local codes.

Attention

CSA: For Canada:
Integral solid state short circuit protection does not provide branch circuit protection. Branch circuit protection must be provided in accordance with the Canadian Electrical Code, part I.

Attention

Operation of this equipment requires detailed installation and operation instructions provided in the Installation/Operation manual intended for use with this product. This information is provided online at www.doc.synapticon.com and can be downloaded as PDF.

A hard copy of this information may be ordered at +49 7031 / 30 478 -0

L’utilisation de cet appareil nécessite des instructions détaillées d’installation et de fonctionnement fournies dans le manuel d’installation/utilisation prévu pour ce produit. Cette information est disponible en ligne sur www.doc.synapticon.com et peut être téléchargée sous forme PDF.

La version papier peut être commandée au +49 7031 / 30 478 -0

Note

Motor overtemperature sensing is not provided and must be provided in the field.