On-site installation guide

Please regard this information when installing the Servo Node.

Installation specifications Servo Node 400 Servo Node 1000 Servo Node 2000
E-File number E506869
Rating in Volt 12-48 V
Rating in Ampere 13.2 A RMS 33 A RMS 66 A RMS
Short circuit current rating 5k A
Maximum Surrounding Air Temperature 40° C
Torque Values for Terminal screws 0.5 - 0.6 Nm (4.4 lbf∙in)
Short circuit rating and fuse type Listed Class T Fuse, rated min. 160Vdc 50A 20kA. (JDDZ/7.E81895)
Temperature rating of field installed conductors >85° N/A

Field wiring terminal marking

../../../../_images/e1_terminal_designation.png

Attention

These products are intended for operation within circuits not connected directly to the supply mains (galvanically isolated from the supply, i.e. on transformer secondary).

Attention

Integral solid state short circuit protection does not provide branch circuit protection. Branch circuit protection must be provided in accordance with the National Electrical Code and any additional local codes.

Attention

CSA: For Canada: Integral solid state short circuit protection does not provide branch circuit protection. Branch circuit protection must be provided in accordance with the Canadian Electrical Code, part I.

Note

Motor overtemperature sensing is not provided and must be provided in the field.