Encoder Configuration

Parameter description

Function

Each encoder can have one of these functions:

  • Commutation,

  • Velocity or

  • Position.

It is of vital importance to have exactly one encoder configured for Commutation so that the motor shaft’s position is known to the commutation algorithm. In case your setup requires it, you can use a different encoder for Position or Velocity. In this case, the demanded and actual velocities will be scaled to the same reference frame of the position.

Resolution

For correct function it is necessary to provide the resolution of the encoder, this value is given in Inc/Revolution, please refer to your encoder’s data sheet.

Important:Please keep in mind that manufacturers sometimes give this specification in differing units. If the resolution according to your data sheet is not given in Inc/Revolution, please convert the value.

Zero velocity threshold

Time without a position change in which the velocity is assumed to be zero. After this time, the velocity value is set to 0 if no new position was received from the encoder. The default value is 5000 µs.

Attention: Expert setting. The default value will perform sufficiently in most cases.

Polarity

The polarity represents the direction of rotation of the motor in comparison to the rotation of the encoder. If these directions don’t match, then the polarity is inverted.

Set the value to -1 to invert the polarity.

Multiturn resolution

In case your encoder supports multiturn functionality, the number of stored revolutions must be specified here.

Note: If an incremental encoder with an index is configured, it will perform an index search procedure after the first transition to Operation Enabled after power down. During this procedure, the motor will be controlled by the Open Loop Field Mode and will rotate until it finds the index. The amount of applied current can be configured by the object 0x2009:2 - Commutation offset: Applied percent of rated torque.

Parameters

Object ID Name Description
0x2009 Commutation offset 0x2009:2: Applied percent of rated torque
0x2110 Encoder 1 configuration Configuration object for Encoder 1
0x2111 Encoder 1 feedback Provides the position or velocity value read at Encoder 1
0x2112 Encoder 2 configuration Configuration object for Encoder 2
0x2113 Encoder 2 feedback Provides the position or velocity value read at Encoder 2
0x2012:9 Position controller: Encoder source Which encoder should be used for position control
0x2011:5 Velocity controller: Encoder source Which encoder should be used for velocity control
0x2010:12 Torque controller: Encoder source Which encoder should be used for torque control and for commutation